Kolbenpumpen werden häufig in Systemen mit hohem Druck, hohem Durchfluss und hoher Leistung sowie dort eingesetzt, wo der Durchfluss reguliert werden muss, z. B. in Mobil- und Baumaschinen, Baufahrzeugen, Hochleistungshobelmaschinen, Metallumformung und -stanzen, Werkzeugmaschinen, Hydraulikpressen, Ölfeldausrüstung, Bergbau- und Metallurgiemaschinen, Schiffs- und andere Hydrauliksysteme.

Modellnummer
| Feature | Unit | Frame | ||||||
|---|---|---|---|---|---|---|---|---|
| 042 | 055 | 075 | 100 | 130 | 180 | 250 | ||
| Displacement | cm3/rev. [in3]/rev. |
42 [256] |
55 [3.35] |
75 (4.59] |
100 [6.10] |
130 (7.93] |
180 (10.98) |
250 [15.25] |
| Flow at rated speed (theoretical) |
l/min. [US gal/min] |
176 [46] |
215 [57] |
270 [71] |
330 [87] |
403 [106] |
468 [124] |
575 [160] |
| Torque at maximum displacement (theoretical) |
N*m/bar [lbf.in/1000 psi] |
0.67 [410] |
0.88 [530] |
1.19 [730] |
1.59 [970] |
2.07 [1260] |
2.87 [1750] |
3.97 [2433] |
| Mass moment of inertia of rotating components |
kg *m2 [slug*ft2] |
0.0023 [0.0017] |
0.0060 [0.0044] |
0.0096 [0.0071] |
0.0150 [0.0111] |
0.023 [0.0170] |
0.0380 [0.0280] |
0.0650 [0.0479] |
| Weight (with control opt .MA) | kg [lb] | 34[75] | 40 [88] | 49[108] | 68[150] | 88[195] | 136 [300] | 154 [340] |
| Mounting (per ISO 3019-1) | Flange 102-2 (SAE B) |
Flange 127-4 (SAEC) |
Flange 152-4 (SAE D) |
Flange 165-4 (SAE E) |
||||
| Rotation | Right hand or Left hand rotation | |||||||
| Main ports:4-bolt split-flange (per SAE J518 code 62) |
mm [in] |
19.05 [0.75] |
25.4 [1.0] |
25.4 (1.0] |
25.4 (1.0) |
31.75 [125] |
31.75 [1.25) |
38.1 (1.5) |
| Main port configuration | Twin poet | Twin or side port | Twin port | |||||
| Case drain ports (SAE O-ring boss) | UNF thread(in) | 0.875-14 | 1.0625-12 | 1.0625-12 | 1.0625-12 | 1.3125-12 | 1.625-12 | 1625-12 |
| Other ports | SAE O-ring boss | |||||||
| Shafts | Splined, and tapered shafts available | |||||||
| Auxiliary mounting | SAE-A.B.C | SAE-A.B.C.D | SAE-A.B,CD.E | |||||
INSTALLATION SIZE







Technische Daten
| Parameter | Unit | Frame | ||||||
|---|---|---|---|---|---|---|---|---|
| 042 | 055 | 075 | 100 | 130 | 180 | 250 | ||
| Input speed | ||||||||
| Minimum | min-3(rpm) | 500 | 500 | 500 | 500 | 500 | 500 | 500 |
| Rated Speed | 4200 | 3900 | 3600 | 3300 | 3100 | 2600 | 2300 | |
| Maximum | 4600 | 4250 | 3950 | 3650 | 3400 | 2850 | 2500 | |
| System pressure | Maximum working pressure | bar | [psi] | 450 | [6525] | |
|---|---|---|---|---|---|---|
| Maximum pressure | 480 | [6960] | ||||
| Maximum low loop | 45 | [650] | ||||
| Minimum low loop pressure | 10 | [145] | ||||
| Charge pressure | Minimum | bar | [psi] | 18 | [261] | |
| Maximum | 34 | [493] | ||||
| Control pressure | Minimum (at corner power for EDC and FNR) | bar | [psi] | 14 | [203] | |
| Minimum (at corner power for NFPE) | 22 | [319] | ||||
| Maximum | 40 | [580] | ||||
| Charge pump inlet pressure | Rated | bar (absolute) | [in Hg vacuum] | 0.7 | [9] | |
| Minimum (cold start) | 02 | [24] | ||||
| Maximum | bar | [psi] | 4.0 | [58] | ||
| Case pressure | Rated | bar | [psi] | 3.0 | [44] | |
| Maximum | 5.0 | [73] | ||||
| Lip seal external pressure | Maximum | bar | [psi] | 0.4 | [15.8] | |
Anwendung
- Serie 90 – fortschrittliche Technologie
- Verstellpumpen in sieben Größen
- Bewährte Zuverlässigkeit und Leistung
- Kompakt, leicht
- Weltweiter Vertrieb und Service
- PLUS+1™-kompatible Steuerungen und Sensoren
Verstellpumpen der Serie 90 sind kompakte Einheiten mit hoher Leistungsdichte. Alle Modelle nutzen das Parallel-Axialkolben-/Slipper-Konzept in Verbindung mit einer neigbaren Taumelscheibe, um die Verdrängung der Pumpe zu variieren. Durch Umkehren des Winkels der Taumelscheibe wird der Ölfluss von der Pumpe umgekehrt Dadurch wird die Drehrichtung des Motorausgangs umgekehrt. Pumpen der Serie 90 verfügen über eine integrierte Ladepumpe zur Systemversorgung
Zum Nachfüllen und Kühlen des Ölflusses sowie zum Steuern des Flüssigkeitsflusses. Sie verfügen außerdem über eine Reihe von Hilfsmontageplatten zur Aufnahme von Hilfshydraulikpumpen für den Einsatz in ergänzenden Hydrauliksystemen. Für eine Vielzahl von Steuersystemen ist eine vollständige Familie von Steuerungsoptionen verfügbar ( mechanisch, hydraulisch, elektrisch). Motoren der Serie 90 verwenden auch die Parallel-Axialkolben-/Slipper-Konstruktion in Verbindung mit einer festen oder neigbaren Taumelscheibe. Sie können Flüssigkeit durch jeden Anschluss ansaugen/ablassen; sie sind bidirektional. Sie verfügen außerdem über eine optionale Schleifenspülfunktion Dies sorgt für zusätzliche Kühlung und Reinigung der Flüssigkeit im Arbeitskreislauf.